   power entry modules with line filter kfc www.schurter.com/pg0 6 emc products iec appliance inlet c14 with filter, fuseholder 1- or 2-pole (5x20 mm or 6.3x32 mm), optional voltage se - lector (step switch) with voltage selector without voltage selector standard- or medical-filter c14 70 c description - panel mount: screw-on mounting from front side - 4 functions: appliance inlet protection class i, fuseholder with interchangeable fuse drawer for fuse-links 5 x 20 mm or 6.3 x 32 mm, with or without vol - tage selector (step switch), line filter in standard and medical version - quick connect terminals 4.8 x 0.8 mm - alternative: version without line filter ke c approvals - vde license number: 40004665 (fko, fkp, fkq, fkr) - ul license number: e72928 (fko, fkp, fkq, fkr) characteristics - all single elements are already wired - the fuse drawer "fingergrip" can be removed by hand for added safety "extra-safe" fuse drawers are available fuse drawer meets requirements of medical standard iec/en 60601-1 the fuse drawer can only be opened with the aid of a tool the fuseholder is accessible from the equipment front - qualified for use in equipment according iec/en 60950 references general product informatio n weblinks approval s , roh s , china-roh s , mating connector s , e-stor e , distributor-stock-chec k , accessorie s technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 10 a @ ta 40 c / 125 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 4.8 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm rated power acceptance @ ta 23 c 5 x 20: 2.5 w (1 pole)/ 2 w (2-pole) per pole 6.3 x 32: 3.15 w (1 pole)/ 2.5 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves voltage selectors optional, step, 3 pos. line filter standard and medical version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 1'700'000 h acc. to mil-hb-217 f
 power entry modules with line filter kfc www.schurter.com/pg0 6 emc products dimensions 69 mm 40.7 50 30 55 4.8x0.8 r 4.5 r 6 r 3.1 42 +0.3 0 0.15 58 27.2 ? 3.2 ? 6.3x90? 28.5 +0.3 0 r 3 0 -0.2 50 230 m3/? 3.6 69 2.8 56 2 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 10 68 2.2 - 2 standard version 2 x 4 68 2.2 - 4 standard version 2 x 1.5 68 2.2 - 6 standard version 2 x 0.8 68 2.2 - 10 standard version 2 x 0.3 68 2.2 - 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1 10 medical version (m5) 2 x 0.3 68 - 1 diagrams standard version with voltage selector x) external connection to be made by the customer 1) line 2) load medical version with voltage selector x) external connection to be made by the customer 1) line 2) load derating curves fuses 5 x 20 mm (1-pole) admissible power ac - ceptance in watt 1.5 1.0 0.5 0.0 2.5 2.0 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c fuses 5 x 20 mm (2-pole, per pole) admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c fuses 6.3 x 32 mm (1-pole) admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 1 00 1.5 1.0 0.5 0.0 2.5 3.15 2.0 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c fuses 6.3 x 32 mm (2-pole, per pole) admissible power ac - ceptance in watt per pole 1.5 1.0 0.5 0.0 2.5 2.0 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c
 power entry modules with line filter kfc www.schurter.com/pg0 6 emc products attenuation loss - - - - differential mode _____ common mode standard version 1 a 2 a 4 a 6 a 10 a medical version (m5) 1 a 2 a 4 a 6 a 10 a variants fuse drawer must be ordered separately (see accessories). rated current [a] filter-type fuseholder voltage selectors order number 1 standard version 1-pole - 4303.5011 2 standard version 1-pole - 4303.5012 4 standard version 1-pole - 4303.5013 6 standard version 1-pole - 4303.5014 10 standard version 1-pole - 4303.5015 1 standard version 1-pole 3 pos. 4303.5031 2 standard version 1-pole 3 pos. 4303.5032 4 standard version 1-pole 3 pos. 4303.5033 6 standard version 1-pole 3 pos. 4303.5034 10 standard version 1-pole 3 pos. 4303.5035 1 standard version 2-pole - 4303.5001 2 standard version 2-pole - 4303.5002 4 standard version 2-pole - 4303.5003 6 standard version 2-pole - 4303.5004 10 standard version 2-pole - 4303.5005 1 standard version 2-pole 3 pos. 4303.5021 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 10 68 2.2 - 2 standard version 2 x 4 68 2.2 - 4 standard version 2 x 1.5 68 2.2 - 6 standard version 2 x 0.8 68 2.2 - 10 standard version 2 x 0.3 68 2.2 - 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1 10 medical version (m5) 2 x 0.3 68 - 1
 power entry modules with line filter kfc www.schurter.com/pg0 6 emc products rated current [a] filter-type fuseholder voltage selectors order number 2 standard version 2-pole 3 pos. 4303.5022 4 standard version 2-pole 3 pos. 4303.5023 6 standard version 2-pole 3 pos. 4303.5024 10 standard version 2-pole 3 pos. 4303.5025 1 medical version (m5) 2-pole 3 pos. 4303.5221 2 medical version (m5) 2-pole 3 pos. 4303.5223 4 medical version (m5) 2-pole 3 pos. 4303.5225 6 medical version (m5) 2-pole 3 pos. 4303.5227 10 medical version (m5) 2-pole 3 pos. 4303.5229 packaging unit 10 pcs required accessor y description fusedrawer 3 fusedrawer for fuse links 5x20mm resp.. 6.3x32mm fingergrip, 5 x 20, 2-pole, voltage selectors 4303.2014.00 fingergrip, 5 x 20, 2-pole, voltage selectors, 100, 120, 220, 240 4303.2014.01 fingergrip, 5 x 20, 2-pole, voltage selectors, 110, 150, 220 4303.2014.02 fingergrip, 5 x 20, 2-pole, voltage selectors, 110, 220 4303.2014.03 ... accessorie s assorted cover s rear cover 0859.0072 cord retaining kit s cord retaining strain relief flat head, a 4700.0001 mating outlets/connector s category / description appliance outlet overview complet e iec appliance outlet f, screw-on mounting, front side, solder or quick-connect terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outlet further types to kf c
 power entry modules with line filter kfc www.schurter.com/pg0 6 emc products connector overview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connector further types to kf c ... power cord overview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cord further types to kf c ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.


▲Up To Search▲   

 
Price & Availability of 43035023

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X